True Induction TI-3B User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 13
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13
Error Code
E1
E2
E3
E4
E5
E6
EE
"---"
Cause and Potential Solution
Voltage is under 75V
Voltage is over 145V
IGBT in short circuit, contact the seller for support.
Temperature sensor is defective. It may be caused by a concave
pot. Change pot and restart the induction process. If the
problem persists then contact the seller for support.
The unit may be damaged, contact the seller for support.
The cooking temperature is over 450 degrees Fahrenheit in the
EG TEMP mode. After the unit has cooled and switches to
standby mode then it can be restarted.
The unit has reached the max cooking time of 150 minutes.
Press POWER key to restart/resume cooking.
No suitable pot or no pot on the induction cooktop.
After pressing POWER key, press HEAT key to start the unit.
VII. Troubleshooting Error Codes Continued...
If the display shows an error code, please reference this sheet for a potential solution: